Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Int. j. high dilution res ; 21(2): 6-6, May 6, 2022.
Article in English | LILACS | ID: biblio-1396757

ABSTRACT

Isotherapics preparedfromtoxic substances have been described as attenuation factors for heavy metal intoxicationin aquatic animals. Herein, Artemia salinaand mercury chloride were usedas a model to identify treatment-related bioresilience. The aim was to describe the effects of Mercurius corrosivus(MC) in different potencies on Artemia salinacyst hatching and on mercury bioavailability. Artemia salinacysts were exposed to 5.0 µg/mL of mercury chloride during the hatching phase. MC6cH, 30cH, and 200cHwere prepared and poured into artificial seawater. Different controls were used (nonchallenged cysts and challenged cysts treated with water, succussed water, and Ethilicum 1cH). Four series of nine experiments were performed for4 weeks to evaluate the percentage of cyst hatchingconsidering all moon phases. Soluble total mercury (THg) levels and precipitated mercury content were also evaluated. Solvatochromic dyes were used to check for eventual physicochemical markers of MCbiological activity. Two-way analysis of variance (ANOVA) with mixed modelswas used for evaluating the effect of different treatments andthe simultaneous influence of the moon phases on the cystshatching rate, at both observation times (24 and 48 hours).When necessary, outliers were removed, using the Tukeycriterion.Thelevel of significance αwas set at 5%. Significant delay (p<0.0001) in cyst hatching was observed after treatment with MC30cH, compared with the controls. An increase inTHg concentration in seawater (p<0.0018) and of chlorine/oxygen ratio (p<0.0001) in suspended micro-aggregateswas also seen, with possiblerelation with mercury bioavailability. Specific interaction of MC30cH with the solvatochromic dye ET33 (p<0.0017) was found. The other observed potencies of Mercurius corrosivus6 and 200 cH were not significant in relation to the observed groups.The results werepostulated as being protective effects of MC30cH on Artemia salina, by improving its bioresilience.


Subject(s)
Artemia , Ecotoxicology , Homeopathy , Mercury
2.
Article | IMSEAR | ID: sea-192291

ABSTRACT

Context: The adhesives clinical effectiveness has been extensively reported for noncarious cervical lesions (NCCLs). However, there is a lack of information about the adhesive systems strategies and their effect on NCCL restoration longevity. Aims: This study aims to evaluate a 42-month performance of four dentin adhesive systems used for the restorative treatment of NCCLs. Settings and Design: NCCLs were randomly divided into four groups: (1) Scotchbond multi-purpose (MP); 2: Single bond plus (SB); 3: Scotchbond SE (SE); and 4: Easy bond (EB). Subjects and Methods: NCCLs (125) were randomly distributed: (1) MP; (2) SB; (3) SE; and (4) EB and were restored with a nanofilled resin-composite, evaluated along 18-36-42 months. Statistical Analysis Used: Kruskal–Wallis test: Comparison among the adhesive systems in each period. Friedman analysis: Comparison along the periods. Kaplan–Meier: Survival analysis. Results: Baseline and 42-month retention (RET) rates (%) were 100/100 for MP; 100/94.74 for SB; 100/87.5 for SE; and 100/100 for EB. The cumulative failure percentage was 9.52% for MP, 9.52% SB, 15.8% SE, and 10% EB. Restorations survival was not dependent on the used adhesive type. Marginal adaptation (MA) was similar to each group, but EB presented noticeable marginal deterioration. Wear was noticed in the 3-step etch-and-rinse (MP) restorations evaluated after 42 months. For the EB, baseline and 18-month wear evaluation were statistically similar. After 36 and 42 months, wear was also similar for EB. Conclusions: Adhesive systems showed similar performance within most important adhesive bonding efficiency achievement parameters: RET, MA, interfacial staining, recurrent caries, and postoperative sensitivity evaluated during 42 months.

3.
Article | IMSEAR | ID: sea-192253

ABSTRACT

Context: Zinc-oxide eugenol (ZOE) is frequently used due to its satisfactory biological response, sedative effect on the pulp, and easy removal. However, literature is very controversial about the influence of the temporary cement-containing eugenol on the bond strength properties. Aims: This study aims to clarify the literature controversy by evaluating the bond strength of ZOE or ZOE-free applied before bonding procedures and the 7-day resting period after the first session. Settings and Designs: Twelve recently extracted third molars were randomly divided into three groups: Group 1: Control (without treatment), Group 2: Temp-Bond NE; Group 3: Temp-Bond. Subjects and Methods: After temporary restorations, the teeth were immersed in distilled water and stored for 7 days at 37°C. The temporary cement was mechanically removed, and prophylaxis was performed. The adhesive procedures were performed, and a 6-mm-high composite resin block was built. The teeth were immediately stored at 100% relative humidity at 37°C for 24 hours. Specimens with 0.7 (±0.2) mm2 of cross-sectional area were obtained and subjected to a microtensile bond strength (μTBS) test at 1 mm/min until failure. Statistical Analysis Used: Analysis of variance (ANOVA) and Tukey's post hoc test were used for statistical analysis. Results: ZOE or ZOE-free cement did not interfere in the μTBS between resin composite and dentine when used with a two-step-etch-rinse adhesive material, considering 7 days of resting period after the first session, by the ANOVA and Tukey's post hoc test (P < 0.05). Conclusions: The authors recommend the removal of the temporary cementation at least seven days after the first session and suggest that the clinicians follow-up further studies to use the cement in case its removal is recommended within a longer period.

4.
J. appl. oral sci ; 22(5): 366-372, Sep-Oct/2014. tab, graf
Article in English | LILACS, BBO | ID: lil-729847

ABSTRACT

Nineteen plant extracts obtained from plants from the Brazilian Amazon showed activity against planktonic Streptococcus mutans, an important bacterium involved in the first steps of biofilm formation and the subsequent initiation of several oral diseases. Objective: Our goal was to verify whether plant extracts that showed activity against planktonic S. mutans could prevent the organization of or even disrupt a single-species biofilm made by the same bacteria. Material and Methods: Plant extracts were tested on a single-bacteria biofilm prepared using the Zürich method. Each plant extract was tested at a concentration 5 times higher than its minimum inhibitory concentration (MIC). Discs of hydroxyapatite were submersed overnight in brain-heart infusion broth enriched with saccharose 5%, which provided sufficient time for biofilm formation. The discs were then submersed in extract solutions for one minute, three times per day, for two subsequent days. The discs were then washed with saline three times, at ten seconds each, after each treatment. Supports were allowed to remain in the enriched medium for one additional night. At the end of the process, the bacteria were removed from the discs by vortexing and were counted. Results: Only two of 19 plant extracts showed activity in the present assay: EB1779, obtained from Dioscorea altissima, and EB1673, obtained from Annona hypoglauca. Although the antibacterial activity of the plant extracts was first observed against planktonic S. mutans, influence over biofilm formation was not necessarily observed in the biofilm model. The present results motivate us to find new natural products to be used in dentistry. .


Subject(s)
Anti-Bacterial Agents/pharmacology , Biofilms/drug effects , Plant Extracts/pharmacology , Plants, Medicinal/chemistry , Streptococcus mutans/drug effects , Analysis of Variance , Bacterial Load , Brazil , Culture Media , Microbial Sensitivity Tests , Reproducibility of Results , Streptococcus mutans/physiology , Time Factors
5.
RFO UPF ; 16(1)jan.-abr. 2011.
Article in Portuguese | LILACS | ID: lil-593682

ABSTRACT

The objective was to evaluate the superficial roughness of a composite resin submitted to different surface treatments, in vitro. Thirty specimens were made with P60TM packable composite resin (3M ESPE), 6 mm thick and 3 mm in diameter. The samples were stored in distilled water for 7 days at 37 ºC and randomly assigned to two test groups. The baseline superficial roughness was determined with a profilometer. Fifteen specimens of each material were subjected to the following finishing and polishing procedures: Group I: multi-fluted burs/aluminum oxide disks (Diamond ProTM, FGM); Group II: multi-fluted burs/rubber tips (Enhance/PogoTM, Dent-sply). Time was limited to 20s per instrument. Following these procedures, it was accomplished a new reading and storage. Then the samples were polished with felt disks with diamond paste (Diamond ExcelTM, FGM), for 20s, and a surface sealant was applied (Biscover, BIS-CO). After all these procedures, the final roughness was determined. Statistical analysis was performed with RM ANOVA and Tukey´s tests (5%). Significant effects were found with both the polishing systems and the sealant (presence or absence). The polishing with Diamond Pro caused the greatest roughness on all composites (p < 0.05). After the application of Biscover the composite surfaces were smoother. This difference was significant for the group polished with Diamond Pro and not sig-nificant for the group polished with EnhanceTM/Pogo. It was concluded that the application of a surface sealant following polishing with aluminum oxide disks or abrasive rubbers results in a surface with smoothness superior to that obtained with these polishing devices alone.

6.
São José dos Campos; s.n; 2008. 191 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: lil-524193

ABSTRACT

Dentes bovinos têm sido convencionalmente utilizados em pesquisas odontológicas substituindo dentes humanos. Diferenças nas propriedades físico-químicas, estruturais e morfológicas dos substratos representarão diferenças na resposta frente a diversos tratamentos. Foi investigada a ablação em esmalte e dentina de dentes bovinos (30) e humanos (30) com laser de Ti: Safira, no regime de femtossegundos (70fs), com λ= 800±1 nm, taxa de repetição=1 KHz, utilizando diferentes potências médias com diferentes tempos de exposição. Foram realizadas análises morfológicas e físico-químicas. Os corpos-de-prova foram observados ao microscópio de luz, ao MEV e analisados por EDX. As microcavidades em esmalte (bovino e humano) apresentaram ablação precisa, integridade e definição das margens. No esmalte humano não houve danos térmicos ou microfraturas; o bovino apresentou microfraturas, provavelmente resultado de sua menor resistência à ablação com laser. As microcavidades da dentina (bovina e humana) apresentaram bordas definidas, entretanto com microfraturas, sendo que na dentina bovina foram mais numerosas, mais amplas e mais intensas, mostrando maior susceptibilidade frente à irradiação com laser. Quanto à proporção Ca/P, as alterações proporcionais entre números de átomos de Ca em relação ao P, não foram estatisticamente significantes, para nenhum tecido. Conclui-se que o laser de Ti: Safira no regime de femtossegundos, além de muito rápido, potente e seguro, tem a vantagem de poder ser bem controlado e preciso, promovendo profundidades pequenas e específicas. Diante dos resultados e dependendo do tipo de tecido, fica evidente a necessidade de prévio conhecimento das diferenças entre eles antes da direta extrapolação dos resultados obtidos em substrato bovino para humano.


Subject(s)
Humans , Animals , Cattle , Dental Enamel , Dentin , Lasers , Microscopy, Electron, Scanning
7.
JBC j. bras. clin. odontol. integr ; 10(52): 86-93, jan.-mar. 2006. ilus, tab, CD-ROM
Article in Portuguese | LILACS, BBO | ID: biblio-851587

ABSTRACT

Para avaliação do comportamento de um material restaurador, diante das forças oclusais, é importante o teste de resistência adesiva ao cisalhamento. Foram utilizados 30 dentes bovinos. Para aferição da espessura da dentina, foi realizado um acesso pelo cíngulo até atingir a câmara pulpar. Desgastou-se o esmalte até o limite amelo-dentinário e, por meio de um micrômetro, aferiu-se a espessura dentinária vestibular. Depois a dentina foi desgastada até atingir a dentina intermediária. Foram formados dois grupos com 15 dentes cada, aleatoriamente. Uma área de 4 mm, na vestibular, foi delimitada com fita adesiva teflon e realizado todo o procedimento adesivo e restaurador com o auxílio de matriz de teflon bipartida. No Grupo I foi utilizado um adesivo de frasco único (Single Bond) e no Grupo II um adesivo autocondicionante (Clearfil SE Bond). Os testes de cisalhamento foram realizados em uma máquina de ensaio universal. Os resultados obtidos foram os seguintes: Grupo I (Single Bond) 5.46 +- 2.10 e Grupo II (Clearfil SE Bond) 5.53 +- 2.53. A análise estatística foi realizada por meio do teste t a 5% de significância, mostrando que não houve diferença significativa entre os grupos avaliados (p>0.05). Concluiu-se que na dentina bovina, o Single Bond e o Clearfil SE Bond apresentaram comportamento semelhante


Subject(s)
Cattle , Animals , Dentin , Dentin-Bonding Agents , Shear Strength , In Vitro Techniques , Materials Testing/statistics & numerical data
8.
Ciênc. odontol. bras ; 9(1): 93-98, jan.-mar. 2006. tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-457200

ABSTRACT

O objetivo deste estudo foi avaliar a propriedade mecânica de resistência à flexão de quatro cimentos resinosos duais: Enforce F, Variolink II, Bistite II DC e Panavia F. Para tanto, foram confeccionados 40 corpos-de-prova (n=10) de 9mm x 1mm x 1mm, através de uma matriz metálica. O cimento resinoso foi levado à matriz em incremento único até o total preenchimento da matriz. Após a fotopolimerização, os espécimes foram armazenados em água destilada a 37ºC por 24h. Em seguida, em cada grupo foi realizado o ensaio mecânico de resistência à flexão de 3 pontos, com uma célula de carga de 50 Kgf, a uma velocidade de 0,5 mm/min. Os resultados foram registrados em MPa, e analisados estatisticamente pelo método de análise de variância e pelo teste de Tukey (5%). Foi observado que os cimentos Bistite II DC e Panavia F apresentaram médias de resistência à flexão significantemente maiores do que os cimentos Variolink II e Enforce F.


Subject(s)
Resin Cements , Tensile Strength
9.
Rev. ABO nac ; 13(3): 179-183, jun.-jul. 2005. ilus
Article in Portuguese | LILACS, BBO | ID: biblio-872710

ABSTRACT

A disponibilidade de dentes humanos para pesquisa científica tem diminuído muito. As Comissões de Bioética estão cada vez mais exigentes em relação ao uso desses dentes nestas pesquisas. Dentes bovinos têm sido utilizados como substitutos, de forma aleatória, sem que se defina se as características dessa dentina são semelhantes à humana. Os objetivos deste trabalho foram, portanto, o de estudar aspectos micromorfológicos da dentina bovina, a fim de normalizar o uso de dentes bovinos, substituindo dentes humanos em pesquisas científicas e embasar novos estudos comparativos, uma vez que a literatura apresenta poucos estudos aprofundados sobre o assunto. Dentes bovinos foram fixados em formal tamponado a 10%. Foram preparadas lâminas pelas técnicas de desgaste e de descalcificação; estas foram coradas por HematoxilinaJEosina e Tricrômico de Masson. Concluiu-se que: dentina bovina apresenta maior número de túbulos dentinários/área próximo à polpa e menor número próximo ao esmalte, semelhante à dentina humana; maior diâmetro nas proximidades do esmalte e menor diâmetro nas proximidades da polpa, ao contrário da dentina humana; a distribuição da dentina intertubular bovina próxima à polpa não foi uniforme ao longo do dente. Considerando estas conclusões, especialmente a que mostra maior diâmetro dos túbulos dentinários próximo ao esmalte, na dentina bovina, é razoável supor alterações em pesquisas que utilizam essa dentina em substituição à dentina humana. Outros estudos devem ser realizados para complementar esses achados.


Subject(s)
Humans , Animals , Cattle , Dental Pulp , Dentin , Tooth
11.
Rev. odonto ciênc ; 19(46): 377-381, out.-dez. 2004. tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-412487

ABSTRACT

O objetivo deste trabalho foi simular in vitro, situações que ocorrem no dia-a-dia do paciente, em relação à absorção de saliva artificial e de um anti-séptico bucal, sobre os materiais restauradores estéticos. Para tanto, foram confeccionados 60 corpos-de-prova (CP) a partir de uma matriz de 5 mm de diâmetro x 3 mm de profundidade. Os CPs foram subdividos em 4 grupos: GI (controle) TPH Spectrum, GII TPH Spectrum, GIII P60 e GIV Esthet-X. Após a fotoativação, os CPs foram identificados e pesados em uma balança analítica de precisão. Em seguida, os CPs foram imersos em saliva artificial, por 7 dias a 37°C. Então, foi realizada nova pesagem, e os CPs dos grupos GII, GIII e GIV foram imersos em anti-séptico bucal e os CPs do grupo GI foram novamente imersos em saliva artificial, todos a 37°C. Foram realizadas mensurações periódicas, após 6, 12 e 36 horas. Resultados: GI (controle): 0,125g ± 0,003; GII:0,120g ± 0,001; GIII: 0,127g ± 0,004 e GIV: 0,120g ± 0,006. Os dados foram submetidos à análise estatística, empregando o teste ANOVA (p > ou = 0,5) e os resultados demonstraram não haver diferença estatística quanto ao peso inicial e final nos grupos estudados. Concluímos que nenhuma das resinas compostas testadas sofreu absorção pela saliva artificial ou anti-séptico bucal no período correspondente a 6 anos de uso diário


Subject(s)
Humans , Mouthwashes , In Vitro Techniques , Composite Resins , Saliva, Artificial , Absorption
SELECTION OF CITATIONS
SEARCH DETAIL